A/C - Blower Motor Runs With Switch In OFF Position

NUMBER: 24-001-11

GROUP: Heating & Air Conditioning

DATE: February 05, 2011

THIS SERVICE BULLETIN IS ALSO BEING RELEASED AS RAPID RESPONSE TRANSMITTAL 11-007. ALL APPLICABLE SOLD AND UN-SOLD VIN's HAVE BEEN LOADED. TO VERIFY THAT THIS SERVICE ACTION IS APPLICABLE TO THE VEHICLE, USE VIP OR PERFORM A VIN SEARCH IN TECHCONNECT. ALL REPAIRS ARE REIMBURSABLE WITHIN THE PROVISIONS OF WARRANTY.

SUBJECT:
HVAC Control Module

OVERVIEW:
This bulletin involves installing a replacing the HVAC Control Module.

MODELS:

2011 MK Patriot

2011 PM Compass

NOTE:
This bulletin applies to vehicles equipped with the manual A/C and Heater Control Module (Sales Code HAA) built between December 23, 2010 (MDH 1223XX) and January 4, 2011 (MDH 0104XX).

SYMPTOM/CONDITION:
Vehicles may exhibit an condition where the HVAC blower motor continues to run even if the switch is in the off position.

DIAGNOSIS:
If customers complain of the symptom condition, perform the following repair procedure.

PARTS REQUIRED:

REPAIR PROCEDURE:

1. Replace the MIC A/C and Heater Control Module per the service information available in DealerCONNECT/TechCONNECT, Group 24 Heating and Air Conditioning > Controls > Control, A/C and Heater > Removal and Installation.

POLICY:
Reimbursable within the provisions of the warranty.





TIME ALLOWANCE:





FAILURE CODE:

Disclaimer: