Installation
EXHAUST PRESSURE SENSOR
1. Install tubing (7) on pressure differential sensor (2).
2. Position pressure differential sensor (2) and tubing (7).
3. Install pressure differential sensor mounting bolt (3). Tighten to 10 Nm (89 in. lbs.).
4. Install downstream pressure tube (6) into catalytic converter. Tighten the fitting to 10 Nm (89 in. lbs.).
5. Install upstream pressure tube (4) into catalytic converter. Tighten the fitting to 10 Nm (89 in. lbs.)
6. Position electrical connector (1) into bracket.
7. Connect negative battery cable.