FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Installation






INSTALLATION





1. Install new NVLD pump o-ring (2) to EVAP canister (1).





2. Position NVLD pump (4) into EVAP canister (1).
3. Rotate pump (4) until tab (3) aligns with notch in EVAP canister (1).





4. Carefully install vapor/vacuum lines (1) and (6) to NVLD pump and EVAP canister. The vapor/vacuum lines and hoses must be firmly connected. Check the vapor/vacuum lines at the NVLD pump, filter and EVAP canister purge solenoid for damage or leaks. If a leak is present, a Diagnostic Trouble Code (DTC) may be set.
5. Connect electrical connector (4) to pump.
6. Install plastic splash shield at rear of left-rear tire.
7. Install left-rear tire.