Removal - Rear
REMOVAL
1. Remove rear HVAC housing (1) and place it on a workbench .
2. Disengage the connector lock and disconnect the rear HVAC wire harness connector (2) from the rear blower motor resistor (3).
3. Remove the two screws (4) that secure the rear blower motor resistor to the rear HVAC housing and remove the resistor.