Driver Demand Sensor Monitor
Driver Demand Sensor monitor
During ignition on conditions the voltages from the two-track driver demand sensor are monitored. If the input voltage stays above a calibration value for more than a calibratable period, the high input failure judgement is made. If the input voltage stays below a calibration value for more than a calibratable period, the low input failure judgement is made. If the angle obtained from sensor 1 differs from the angle obtained from sensor 2 by more than a calibratable amount for more than a calibration period a range / performance failure judgement is made.