Battery Reconnection Procedure
1. Connect the battery terminal(s).
NOTE: Whether one, or both, cables are disconnected, a minimum of 30 seconds MUST elapse between disconnection of the FIRST cable & reconnection of the LAST cable. A clean final connection must be made; do not allow temporary contact.
2. Reset the clock.
3. Enter the radio security code.
4. With doors closed, cycle (both) door drop glass up and down to establish the upper and lower datum points.
Switch the ignition ON.
Lower the glass to the stop and hold the switch in the DOWN position for a further five seconds.
Raise the glass fully and hold the switch in the UP position for a further five seconds.
5. Switch the ignition OFF.