Specification for Recovery/Recycle/Recharge Equipment
Specification For Recovery/Recycle/Recharge Equipment
NOTE: ppm = parts per million
Feature Requirement
Recovery rate 0.014 - 0.062 m3/min. (1.36 kg in 20 minutes)
Cleaning capability 15 ppm moisture; 4000 ppm oil; 330 ppm
non-condensable gases in air
Oil separator With hermetic compressor and automatic oil return
Moisture indicator Sight-glass type, sensitive to
15 ppm minimum
Vacuum pump Two-stage 0.07 - 0.121 m3/min.
Filter Replaceable, with moisture indicator
Charge Selectable charge weight and automatic delivery
Hoses Dedicated HFC 134A port connections
Charge pressure Heating element to increase pressure