No Cooling
No Cooling
Possible Source(s):
- Compressor seized
- Compressor seal failure
- Compressor valve or piston damage
Action(s) to take:
- Renew compressor
Possible Source(s):
- Compressor clutch/circuit faulty
Action(s) to take:
- Refer to PDU
Possible Source(s):
- Drive belt slack/broken
Action(s) to take:
- Adjust or renew
Possible Source(s):
- Blower motor/circuit faulty
- Pressure switch/circuit fault
Action(s) to take:
- Refer to PDU
Possible Source(s):
- Total loss of refrigerant caused by broken pipe or joint
Action(s) to take:
- Repair/renew. Check code 23
Possible Source(s):
- Partial loss of refrigerant caused by leaking joint or pipe
Action(s) to take:
- Repair/renew, check fault code #23
Possible Source(s):
- Condenser damage
Action(s) to take:
- Renew, check fault code #23
Possible Source(s):
- Blocked receiver/drier filter
Action(s) to take:
- Renew receiver/drier
Possible Source(s):
- Evaporator sensor/circuit faulty
Action(s) to take:
- Refer to PDU, check fault code #13
Possible Source(s):
- Blocked pollen filter (if fitted)
Action(s) to take:
- Clean or renew