Insufficient Heating
Insufficient Heating
Possible Source(s):
- Coolant flow valve stuck 'closed'
- Coolant flow valve stuck 'open' allowing recirculation of coolant at engine idle
Action(s) to take:
- Renew valve
Possible Source(s):
- Motorized in-car aspirator seized
Action(s) to take:
- Renew aspirator
Possible Source(s):
- Cool air bypass damper stuck open
Action(s) to take:
- Renew, check fault code #43
Possible Source(s):
- Blocked air inlet/pollen filter
Action(s) to take:
- Check/clean/renew
Possible Source(s):
- Blower speed low
Action(s) to take:
- Check performance range
Possible Source(s):
- Low coolant level
Action(s) to take:
- Adjust as required (verify and correct reason for loss)
Possible Source(s):
- Engine thermostat faulty
Action(s) to take:
- Check engine running temperature
Possible Source(s):
- Heater water pump seized
Action(s) to take:
- Check operation
Possible Source(s):
- Heater matrix blocked
Action(s) to take:
- Renew matrix
Possible Source(s):
- Heater circuit air-lock
Action(s) to take:
- Perform Cooling System fill/bleed procedure.