Introduction
Introduction
It is very important to positively identify the area of concern before starting a rectification procedure. A little time spent with your customer to identify the conditions under which a problem occurs will be beneficial. See below for example:
Condition(s):
No defrost
Possible Source(s):
- No airflow to windshield
Action(s) to take:
- Check blowers and flaps
Possible Source(s):
- No function in defrost mode
Action(s) to take:
- Check A/CCM
Possible Source(s):
- Mode selection not available
Action(s) to take:
- Check control panel communication
Possible Source(s):
- Airflow OK but no heat
Action(s) to take:
- Check water pump and valve
Relevant criteria are: Weather conditions, ambient temperature, intermittent or continuous fault, airflow fault, temperature control fault, distribution fault and air inlet problem.