Vehicle Damage Warnings



Precautions


Plug pipes and units immediately after disconnection and do not remove the plugs until immediately before making the connection. Do not leave the system open to atmosphere.

The receiver drier must be renewed if the compressor has failed or if it is suspected that debris may be present in the system.

It is not always necessary to renew the receiver drier if the correct procedures have been followed. However, if a component or part of the system is left dismantled for more than five minutes, it may be advisable to renew the receiver drier. This guidance is based on UK average humidity levels; locations with lower humidity levels will be less critical to moisture contamination. It must be stressed however that there is not a safe period for work to be carried out in.

Do not use any replacement parts supplied without transit plugs and seals-return them to the supplier.

Diagnostic equipment for pressure, mass and volume should be calibrated regularly and certified by a third party organization.

Use extreme care when handling and securing aluminum fittings; always use a backing spanner and take special care when handling the evaporator.

Use only the correct or recommended tools for the job and apply the manufacturer's torque specifications.