C5: Check For O2 Sensor Failure
With the conditions held as in C4, run the engine at 1500 rpm for approximately 3 minutes.
Does the displayed voltage drop below 400mV and rise above 500mV, cycling approximately every 180 seconds?
Yes
GO to C7, C7: Check For O2 Sensor Continuity
No
Renew O2 sensor and reconnect plug(s).
GO to C6, C6: Stop