U5: Check Harness Signal Continuity
With, EM011, & PI042 disconnected, measure the resistance between EM011/013 & PI042/001
Is the resistance < 0.5 ohms?
Yes
Go to U6
No
Inspect EM011 & PI042 for bent/pushed back pins or locate & repair the harness/connector PI001/012. Test the system for normal operation