G15: O2 Sensor Screen Ground Continuity
With EM012 & EM024 disconnected, measure the resistance between EM012/022 & EM024/001
Is the resistance < 0.5 ohms?
Yes
Go to G16
No
Inspect connectors EM012, & EM024 for corrosion, damaged / pushed back pins or repair the harness; reconnect plug(s)
Go to G20