A13: Heated O2 Sensor Screen Ground Continuity
With EM012 & EM021 disconnected, measure the resistance between EM012/022 & EM021/004
Is the resistance < 0.5 Ohms?
Yes
Go to A14 A14: Check For Short to B+
No
Inspect connectors EM012 & EM021 for corrosion, damaged / pushed back pins or repair the harness; reconnect plug(s).
Go to A18 A18: End