Specification for Recovery/Recycle/Recharge Equipment
Specification For Recovery/Recycle/Recharge Equipment
NOTE: ppm = parts per million
Feature Requirement
Recovery rate 0,014 - 0,062 m3 / min. (1,36 kg in 20 minutes)
Gleaning capability 15 ppm moisture; 4000 ppm oil; 330 ppm non-condensable gases in air
Oil separator With hermetic compressor and automatic oil return
Moisture indicator sight-glass type, sensitive to 15 ppm minimum
Vacuum pump Two-stage 0,07 - 0,127 m3 / min.
Filter Replaceable, with moisture indicator
Charge selectable charge weight and automatic delivery
Hoses Dedicated HFC 134A port connections
Charge pressure Heating element to increase pressure