Generator, General Repair Notes
The following notes are common to AJ16 & V12 engined vehicles.CAUTION: Always disconnect the battery ground lead before commencing with any instrument renewal procedures.
- To remove the generators, jack up the front of the vehicle on to two jacking points.
- Prior to removing the generator, ensure that all relevant electrical linkages to the generator are disconnected.
- For drive belt tensioning data see 'Engine, Drive Belts, Mounts, Brackets and Accessories, Drive Belt, Specifcations.' Specifications