System Components Serviced/Replaced
System Components Serviced/Replaced
Should a major component such as condenser, receiver/drier or evaporator be renewed then an adjustment to the system oil level must be made. This may be carried out in the same way as the examples for the compressor except for the fact that trapped oil within any one of these components cannot normally be drained. Therefore, a nominal amount of oil should be substituted in addition to that recovered from the recovery station separator.
Condenser Add 40 ml
Evaporator Add 40 ml
Receiver/drier NO adjustment
CAUTION: Always decant fresh oil from a sealed container and do not leave oil exposed to the atmosphere. PAG oil is very hygroscopic (absorbs water) and will rapidly attract atmospheric moisture.
PAG oil must NEVER be mixed with mineral based oils. Do not re-use oil following a recovery cycle, dispose of it safely.