Evaporator Temperature Sensor / Switch: Testing and Inspection
Thermo Switch (Electronic Thermostat and Fin Sensor)Inspection
Electronic Thermostat
1. With the air selector knob set to "FACE" and the air-source selector lever to "RECIRC", start the air conditioning.
2. While shifting the temperature control lever from "MAX COOL" through the "MAX HOT", check to see if the magnetic clutch turns on and off. (* Note that the time required to reach the "OFF" point depends on the warm or cold air at 1.8 °C (35.2 °F) at the electronic thermostat fin sensor.)
3. While the magnetic clutch is turning "ON" and "OFF", measure the voltage between chassis side connector terminal No.3 No.5.