Installation
Condenser ASMInstallation
To install, follow the removal steps in the reverse order, noting the following points.
1. When mounting a new condenser ASM, add 30 cc (1.0 US fl oz) of compressor oil.
2. Do not reuse O-rings. Make sure to replace them with new ones.
3. Always apply a layer of compressor oil to the new O-rings before connecting the pipe.
4. Tighten the high pressure hose to the specified torque.