Symptom Related Diagnostic Procedures
POWER WINDOW RETAINED POWER FUNCTION DOES NOT OPERATE NORMALLY
Description
Retained power function does not operate after ignition switch turns OFF.
Diagnosis Procedure
1. CHECK DOOR SWITCH
Check door switch.
Refer to "Component Function Check" Door Switch.
Is the inspection result normal?
YES- GO TO 2.
NO- Repair or replace the malfunctioning parts.
2. CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES- Check intermittent incident. Refer to "Intermittent Incident" Intermittent Incident.
NO- GO TO 1.