Compressor Control Function
COMPRESSOR CONTROL FUNCTION
Fail-safe
FAIL-SAFE FUNCTION
If a communication error exists between the unified meter and A/C amp., and the AV control unit and preset switch for 30 seconds or longer, air conditioning system is controlled under the following conditions:
Compressor: ON
Air outlet: AUTO
Air inlet: FRE (Fresh)
Fan speed: AUTO
Set temperature: Setting before communication error occurs