Diagnosis Procedure
TRUNK LID AUTO CLOSURE SYSTEM DOES NOT OPERATE
OPEN FUNCTION : Diagnosis Procedure
1. CHECK STRIKER SWITCH
Check striker switch.
Refer to "Component Function Check" Striker Switch.
Is the inspection result normal?
YES- GO TO 2.
NO- Repair or replace the malfunctioning parts.
2. REPLACE TRUNK CLOSURE CONTROL UNIT
- Replace trunk closure control unit. Refer to "TRUNK LID STRIKER : Removal and Installation" Removal and Installation.
- Confirm the operation after replacement.
Is the result normal?
YES- INSPECTION END
NO- Check intermittent incident. Refer to "Intermittent Incident" Intermittent Incident.