Door Key Cylinder Switch Does Not Operate Power Windows
DOOR KEY CYLINDER SWITCH DOES NOT OPERATE POWER WINDOWS
Diagnosis Procedure
1. PERFORM INITIALIZATION PROCEDURE
Perform Initialization procedure and check that inspection result is normal.
Work Procedure
Is the inspection result normal?
YES- INSPECTION END
NO- GO TO 2.
2. CHECK DRIVER SIDE DOOR LOCK ASSEMBLY (DOOR KEY CYLINDER SWITCH)
Check driver side door lock assembly (door key cylinder switch).
Door Key Cylinder Switch
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace the malfunctioning parts.
3. CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES- Check intermittent incident. Intermittent Incident
NO- GO TO 1.