Buzzer (Combination Meter)
BUZZER (COMBINATION METER)
Description
Performs operation method guide and warning with buzzer.
Component Function Check
1. CHECK FUNCTION
1.Use CONSULT to perform Active Test ("INSIDE BUZZER").
2.Touch "TAKE OUT", "KNOB"or "KEY" to check that it works normally.
Is the inspection result normal?
Yes- Warning buzzer into combination meter is OK.
No- .
Diagnosis Procedure
1. CHECK METER BUZZER CIRCUIT
Meter Buzzer Circuit.
Is the inspection result normal?
Yes- GO TO 2.
No- Repair or replace harness.
2. CHECK INTERMITTENT INCIDENT
Intermittent Incident.
- INSPECTION END