Key ID Warning Does Not Operate
KEY ID WARNING DOES NOT OPERATE
Diagnosis Procedure
1. CHECK INTELLIGENT KEY
Check Intelligent Key.
Intelligent Key.
Is the inspection result normal?
YES- GO TO 2.
NO- Repair or replace the malfunctioning parts.
2. CHECK COMBINATION METER DISPLAY FUNCTION
Check combination meter display function.
Combination Meter Display Function.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace the malfunctioning parts.
3. CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES- Check intermittent incident. Intermittent Incident.
NO- GO TO 1.