Striker Switch
STRIKER SWITCH
Description
It is integrated in trunk closure assembly and detects open/close state of trunk lid.
Component Function Check
1. CHECK FUNCTION
1.Turn ignition switch OFF.
2.Check that waiting operation of trunk lid auto closure system operates normally when trunk lid is open.
Is the inspection result normal?
YES- Striker switch is OK.
NO- .
Diagnosis Procedure
1. CHECK STRIKER SWITCH INPUT SIGNAL
1.Turn ignition switch OFF.
2.Disconnect striker switch connector.
3.Check voltage between striker switch harness connector and ground.
Is the inspection result normal?
YES- GO TO 3.
NO- GO TO 2.
2. CHECK STRIKER SWITCH CIRCUIT
1.Disconnect trunk closure control unit connector.
2.Check continuity between trunk closure control unit harness connector and striker switch harness connector.
3.Check continuity between trunk closure control unit harness connector and ground.
Is the inspection result normal?
YES- Replace trunk closure control unit. Removal and Installation.
NO- Repair or replace harness.
3. CHECK STRIKER SWITCH GROUND CIRCUIT
Check continuity between striker switch harness connector and ground.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair or replace harness.
4. CHECK STRIKER SWITCH
.
Is the inspection result normal?
YES- GO TO 5.
NO- Replace striker switch (trunk closure assembly). Removal and Installation.
5. CHECK INTERMITTENT INCIDENT
Intermittent Incident.
- INSPECTION END
Component Inspection
1. CHECK STRIKER SWITCH
1.Turn ignition switch OFF.
2.Disconnect striker switch connector.
3.Check continuity between striker switch terminals.
Is the inspection result normal?
YES- INSPECTION END
NO- Replace striker switch (trunk closure assembly). Removal and Installation.