Keyless Power Window Down Does Not Operate
KEYLESS POWER WINDOW DOWN DOES NOT OPERATE
Description
NOTE:
Before performing the diagnosis in the following procedure, check " Work Flow". Work Flow.
Diagnosis Procedure
1.CHECK REMOTE KEYLESS ENTRY FUNCTION
Check remote keyless entry function.
Does door lock/unlock with Intelligent key button?
YES - GO TO 2.
NO - Go to System Description.
2.CHECK POWER WINDOW OPERATION
Check power window operation.
Does power window up/down with power window main switch?
YES - GO TO 3.
NO - Go to Power Window Main Switch.
3.CHECK "PW DOWN SET" SETTING IN "WORK SUPPORT"
Check "PW DOWN SET" setting in "WORK SUPPORT". Intelligent Key.
Is the inspection result normal?
YES - GO TO 4.
NO - Set "PW DOWN SET" setting in "WORK SUPPORT".
4.CHECK POWER WINDOW MAIN SWITCH SERIAL LINK CIRCUIT
Check power window main switch serial link circuit. Power Window Main Switch.
Is the inspection result normal?
YES - GO TO 5.
NO - Repair or replace the malfunctioning parts.
5.CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES - Check intermittent incident. Intermittent Incident.
NO - GO TO 1.