Work Procedure
CONFIGURATION (HVAC)
Work Procedure
1.WRITING MODE SELECTION
CONSULT-III Configuration
Select "CONFIGURATION" of A/C auto amp..
When writing saved data-GO TO 2.
When writing manually-GO TO 3.
2.PERFORM "WRITE CONFIGURATION - CONFIG FILE"
CONSULT-III Configuration
Perform "WRITE CONFIGURATION - Config file".
- WORK END
3.PERFORM "WRITE CONFIGURATION - MANUAL SETTING"
CONSULT-III Configuration
1. Select "WRITE CONFIGURATION - Manual setting".
2. Select "SETTING".
3. Select "OK".
4. When "COMMAND FINISHED", select "END".
- GO TO 4.
4.OPERATION CHECK
Confirm that each function controlled by A/C auto amp. operates normally.
- WORK END