Automatic Air Conditioner System (With Forest Air)
AUTOMATIC AIR CONDITIONING SYSTEM (WITH FOREST AIR) : Fail-safe
FAIL-SAFE FUNCTION
When a communication malfunction between A/C auto amp. and AV control unit and multifunction switch continued for approximately 30 seconds or more, control the air conditioning under the following conditions.
Compressor :ON
Air Outlet :AUTO
Air Inlet :FRE (Fresh air intake)
Fan speed :AUTO
Set temperature :Setting before communication malfunction