Hazard Function
HAZARD FUNCTION
Description
Performs answer-back for each operation with number of blinks.
Component Function Check
1.CHECK FUNCTION
1. Use CONSULT-III to perform Active Test ("FLASHER").
2. Touch "LH" or "RH" to check that it works normally.
Is the inspection result normal?
YES - Hazard warning lamp circuit is OK.
NO - SEE Diagnosis Procedure.
Diagnosis Procedure
1.CHECK HAZARD SWITCH CIRCUIT
[1][2]Electrical Diagrams.
Is the inspection result normal?
YES - GO TO 2.
NO - Repair or replace harness.
2.CHECK INTERMITTENT INCIDENT
Intermittent Incident.
- INSPECTION END