Key Id Warning Does Not Operate
KEY ID WARNING DOES NOT OPERATE
Description
NOTE:
Warning functions operating condition is extremely complicated. During operation confirmation reconfirm the list above twice in order to check for normal operation. Warning Function.
Diagnosis Procedure
1.CHECK INTELLIGENT KEY
Check Intelligent Key. Intelligent Key.
Is the inspection result normal?
YES - GO TO 2.
NO - Repair or replace the malfunctioning parts.
2.CHECK COMBINATION METER DISPLAY FUNCTION
Check combination meter display function. Combination Meter Display Function.
Is the inspection result normal?
YES - GO TO 3.
NO - Repair or replace the malfunctioning parts.
3.CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES - Check intermittent incident. Intermittent Incident.
NO - GO TO 1.