FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Work Procedure





INITIALIZATION OF ROOF SYSTEM


Work Procedure

1.INSPECTION START
Will CONSULT-III be used?
Will CONSULT-III be used?
YES - GO TO 2.
NO - GO TO 7.
2. STEP 1
With CONSULT-III
1. Start engine.
2. Fully close retractable hard top.
- GO TO 3.
3. STEP 2
Check the operation.
What was the operation performed?
Replace or remove and install roof components.-GO TO 4.
Replace retractable hard top control unit.-GO TO 5.
4. STEP 3
Perform "ROOF STATE RESET" in "Work Support" mode of "RETRACTABLE HARD TOP" using CONSULT-III and erase the current memorized position. Scan Tool Testing and Procedures.
- GO TO 5.
5. STEP 4
Perform "ROOF STATE LEARNING" in "Work Support" mode of "RETRACTABLE HARD TOP" using CONSULT-III and memorize the new roof position. Scan Tool Testing and Procedures.
Fully close the roof and repeat this operation (STEP 4), if roof warning buzzer sounds twice or does not sound during the initialization.

NOTE:
Retractable hard top operation during this procedure is as per the following items.
1. Roof warning buzzer sounds once at the same time retractable hard top open operation is performed by roof open/close switch (OPEN) operation, after touching "Start" on CONSULT-III screen.
2. Roof warning buzzer sounds once when the roof is fully open.
3. Roof warning buzzer sounds once at the same time retractable hard top close operation is performed by roof open/close switch (CLOSE) operation.
4. Roof warning buzzer sounds once when the roof is fully closed.
- GO TO 6.
6. STEP 5
Check that retractable hard top operates normally by operating from fully closed to fully open positions and from fully open to fully closed positions.
- WORK END
7. STEP 1
Without CONSULT-III
1. Start engine.
2. Press and hold OPEN or CLOSE of roof open/close switch and check that parcel shelf and roof latch* stop after operating.
*: Depending on the operation ( Description), roof latch may not operate.
Does roof warning buzzer sounds once at the same time parcel shelf stops?
YES - GO TO 9.
NO - GO TO 8.
8. STEP 2
Repeat operation of step 1 until roof warning buzzer sounds once at the same time parcel shelf stops.
- GO TO 9.
9. STEP 3
Check that retractable hard top operates normally by operating from fully closed to fully open positions and from fully open to fully closed positions.
- WORK END