P1610
P1610 LOCK MODE
Description
When the starting operation is carried more than five times consecutively under the following conditions, NATS shifts to the mode that prevents the engine from being started.
- Unregistered Intelligent Key is used.
- BCM or ECM is malfunctioning.
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON.
2. Check "Self-diagnostic result" using CONSULT-III.
Is DTC detected?
YES - Go to P1610.
NO - INSPECTION END
Diagnosis Procedure
1.CHECK ENGINE START FUNCTION
1. Perform the check for DTC except DTC P1610.
2. Use CONSULT-III to erase DTC after fixing.
3. Turn ignition switch OFF.
4. Turn ignition switch ON when registered Intelligent Key is inserted into key slot and wait for 5 seconds.
5. Turn the ignition switch OFF and wait 5 seconds.
6. Repeat steps 4 and 5 twice (a total of 3 times).
7. Check that engine can start when registered Intelligent Key is inserted into key slot.
- INSPECTION END