FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Seat Belt Warning Lamp Does Not Turn On





SEAT BELT WARNING LAMP DOES NOT TURN ON


Diagnosis Procedure

1.CHECK SELF-DIAGNOSIS RESULT
Perform "COMBINATION METER" self-diagnostic result. Refer to Testing and Inspection
Is DTC detected?
YES - Repair or replace the malfunctioning parts.
NO - GO TO 2.
2.CHECK POWER SUPPLY
Check that fuses are not blown.
Check ignition power supply of combination meter. Refer to Power Supply and Ground Circuit
Is the inspection result normal?
YES - GO TO 3.
NO - Repair or replace the malfunctioning parts.
3.CHECK SEAT BELT BUCKLE SWITCH (DRIVER SIDE)
Check seat belt buckle switch (driver side). Refer to Component Function Check
Is the inspection result normal?
YES - GO TO 4.
NO - Repair or replace the malfunctioning parts.
4. .CHECK SEAT BELT BUCKLE SWITCH (PASSENGER SIDE)
Check seat belt buckle switch (passenger side). Refer to Component Function Check
Is the inspection result normal?
YES - GO TO 5.
NO - Repair or replace the malfunctioning parts.
5. .CHECK SEAT BELT WARNING LAMP CIRCUIT
Check seat belt warning lamp circuit. Refer to Seat Belt Warning Lamp Circuit
Is the inspection result normal?
YES - GO TO 6.
NO - Repair or replace the malfunctioning parts.
6.CONFIRM THE OPERATION
Confirm the operation again.
Is the inspection result normal?
YES - Check intermittent incident. Refer to Intermittent Incident.
NO - GO TO 1.