PDM Relay Box
Inspection
IG 1 Relay
Check for continuity between the terminals.
1. There should be continuity between the No.4 in the connector A and No.12 in the connector B terminals when power and ground are connected to the No.2 in the connector A and No.14 in the connector B.
2. There should be no continuity between the No.4 in the connector A and No.12 in the connector B terminals when power is disconnected.
IG 2 Relay
Check for continuity between the terminals.
1. There should be continuity between the No.1 in the connector A and No.10 in the connector B terminals when power and ground are connected to the No.7 in the connector A and No.13 in the connector B.
2. There should be no continuity between the No.1 in the connector A and No.10 in the connector B terminals when power is disconnected.
ACC Relay
Check for continuity between the terminals.
1. There should be continuity between the No.3 in the connector A and No.9 in the connector B terminals when power and ground are connected to the No.7 and No.8 in the connector B.
2. There should be no continuity between the No.3 in the connector A and No.9 in the connector B terminals when power is disconnected.
Sub Start Relay
Check for continuity between the terminals.
1. There should be continuity between the No.2 and No.3 in the connector B terminals when power and ground are connected to the No.4 and No.5 in the connector B.