Diagnostic Trouble Code Descriptions
Troubleshooting
Diagnostic Trouble Codes(Inspection Procedure)
Check the Diagnostic Trouble Codes
1. Turn the ignition switch to OFF.
2. Connect the Hi-scan tool to the DLC connector for diagnosis.
3. Turn the ignition switch to ON.
4. Check the diagnostic trouble codes using the Hi-scan tool.
5. Read the output diagnostic trouble codes. Then follow the remedy procedures according to the "DIAGNOSTIC TROUBLE CODE DESCRIPTION" on the following pages.
NOTE:
- A maximum of 10 diagnostic trouble codes (in the sequence of occurrence) can be stored in the Random Access Memory (RAM) incorporated within the control module.
- The same diagnostic trouble code can be stored one time only.
- If the number of stored diagnostic trouble codes or diagnostic trouble patterns exceeds 10, already stored diagnostic trouble codes will be erased in sequence, beginning with the oldest.
- If the same trouble code does not occur during 40 times continuously, memorized trouble code would be deleted automatically when the ATF temperature reaches 50°C(122°F).
6. Delete the diagnostic trouble code.
7. Disconnect the Hi-scan tool.
NOTE:
DTC cleaning should only be done with the scan tool.
Inspection Chart For Diagnostic Trouble Codes(DTC)