Repair Procedures
Replacement
1. Disconnect the negative (-) battery terminal.
2. Using the screwdriver, remove the center facia panel(A).
3. Disconnect the connectors(A) and then remove the center fascia panel(B).
4. Remove the glove box housing.
5. Disconnect the temp control(A).
6. Using the screwdriver, remove the control panel(A) and then disconnect the connectors(B).
7. Installation is the reverse order of removal.