Blower Motor: Service and Repair
Replacement
1. Disconnect the negative (-) battery terminal.
2. Remove the crash pad under cover .
3. Disconnect the connector of the blower motor.
4. Remove the blower motor (B) after loosening the mounting screws.
5. Installation is the reverse order of removal.