Tail Lamp: Testing and Inspection
Inspection
Tail Lamp
Check for continuity between the terminals.
1. There should be continuity between the No.2 terminal in the I/P-H and the No.15(LH) or 4(RH) terminal in the I/P-G when power and ground are connected to the No.2 terminal in the I/P-H and the No.6 terminal in the I/P-D.
2. There should be no continuity between the No.2 terminal in the I/P-H and the No.15(LH) or 4(RH) terminal in the I/P-G when power and ground are connected to the No.2 terminal in the I/P-H and the No.6 terminal in the I/P-D.