Visual/Physical Inspection
Visual / Physical Inspection
1. Check immobilizer lamp circuit
(1) Ignition "ON" & Engine "OFF"
(2) Check if immobilizer lamp operates properly.
NOTE:
** Right after ignition "ON", Immobilizer lamp lights up for 30 sec.
If lamp blinks 5 times after ignition "ON", there's any fault in immobilizer system.
(3) Is immobilizer lamp operates properly ?
YES
> Check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.
NO
> Go to "Component Inspection" procedure.