System Inspection
System Inspection
Back up Voltage Inspection
1. Ignition "OFF".
2. Disconnect ECM connector.
3. Ignition "ON".
4. Measure voltage between terminal 6 of the ECM harness connector and chassis ground.
Specification : Remain stable at battery voltage
5. Are circuits remaining stable at battery voltage ?