Component Inspection
Component Inspection
1. Ignition "OFF"
2. Measure voltage between terminal 3 of the sensor harness connector and chassis ground (Do not disconnect FTPS harness connector)
Specification : Voltage increases proportionally with decreasing pressure (Approx. 2.5V to 4.5V)
3. Is voltage within the specification ?