W/Harness Inspection
Terminal and Connector Inspection
1. Many malfunctions in the electrical system are caused by poor harness and terminals.
Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found ?
Signal Circuit Inspection
Check for open in harness
1. Ignition "OFF".
2. Disconnect incar temp.sensor.
3. Measure resistance between terminal "4" of incar temp.sensor and terminal "5" of A/C Control Unit
Specification : Approx. 0 Ohms
4. Is the measured resistance within specifications ?
Ground Circuit inspection
Check for open in ground harness
1. Ignition "OFF".
2. Disconnect incar temp.sensor.
3. Measure resistance between terminal "2" of incar temp.sensor and terminal "12" of A/C Control Unit.
Specification : Approx. 0 Ohms
4. Is the measured resistance within specifications ?