Monitor Scantool Data
Monitor Scantool Data
1. Connect scantool to Data Link Connector (DLC).
2. Engine "ON".
3. Monitor the "Intake potentiometer" Parameter on the Scantool. While operating Intake switch.
4. Are the DTC B1208 present and is parameter of "Intake potentiometer" fixed ?
NOTE:
** Parameter of "Intake potentiometer" will be fixed at 100% (or any value above 90%), or 0% (or any value below 10%), if there is any fault in Intake actuator.