Hazard Warning Switch: Testing and Inspection
HAZARD SWITCHINSPECTION
1. Disconnect the negative (-) battery terminal.
2. Remove the center facia panel (B) after opening the astray (A).
3. Disconnect the hazard lamp switch connector (A).
4. Operate the switch and check for continuity between terminal No. 3 and No. 11 with an ohmmeter.