P0453
DTC P0453 EVAP Emission Control System Pressure Sensor High InputDESCRIPTION
The evaporative emissions system prevents hydrocarbon vapors from escaping from the fuel tank into the atmosphere where they could form photochemical smog. Gasoline vapors are collected in the charcoal canister. The Fuel Tank Pressure Sensor (FTPS) is an integral part of the evaporative monitoring system. The ECM monitors the FTPS signal to detect vacuum decay and excess vacuum. The FTPS measures the difference between the air pressure inside the fuel tank and outside air pressure to check purge control solenoid valve operation and for leak detection in the evaporative emissions system by monitoring pressure and vacuum levels in the fuel tank during the purge control solenoid valve operating cycles.
DTC Detecting Condition:
Specifications:
Schematic Diagram:
Step 1 - 2:
Step 3 - 5:
Step 5 (continued):
INSPECTION PROCEDURE