Refrigerant Pressure Sensor / Switch: Service and Repair
REMOVAL1. Discharge the air conditioning system.
2. Disconnect connector from the triple (dual) pressure switch.
3. Remove the triple (dual) pressure switch using the wrench.
NOTE
- Cap the open fitting immediately to keep moisture out of the system.
- Be careful not to twist tubes.
INSTALLATION
1. Installation is the reverse of removal.
2. Evacuate, charge and test refrigeration system.