Shift Interlock Solenoid: Testing and Inspection
A/T KEY INTERLOCK SOLENOID1. Remove the solenoid connector.
2. Using an ohmmeter, measure the resistance between terminals.
Standard resistance : 12 - 16 Ohm
3. Attach the positive (+) lead from the battery to terminal #2. and the negative (-) lead to terminal #1.
4. Check that an operation noise can be heard from the solenoid.