Evacuating Refrigerant System
- When an A/C system has been opened to the atmosphere, such as during installation or repair, it must be evacuated using a vacuum pump.- Start the pump, then open both gauge valves. Turn the pump for about 15 minutes. Close the valves stop the pump. The low gauge should indicate above 700 mmHg (27 in-Hg) and remain steady with the valves closed.
NOTE: If low pressure does not reach more than 700 mmHg (27 in-Hg) in 15 minutes, there is probably a leak in the system. Check for leaks, and repair.
- If there are no leaks open the valves and continue pumping for at least another 15 minutes, then close both valves and stop the pump.